  Datasheet File OCR Text:
  technical d at asheet pmt panel mount power supply 24v 200w 1 phase / pmt - 24v200w1a all parameters are specified at 25 c ambient unless otherwise noted. www. deltapsu .com ( august 2013 , rev. 0 0 ) 1 pmt highlights & features ? ac input voltage selectable by switch ? full aluminium casing for light weight and corrosion resistant handling ? convection cooling ? cold start -20 c at 100% load (200w) ? low leakage current < 0.25ma @ 240vac ? high mtbf > 7 00,000 hrs. as per telcordia sr - 332 ? short circuit / overvoltage / overcurrent / over temperature protections safety standards cb certified for worldwide use model number: pmt -24v200 w1a ?? unit weight : 0 . 63 kg dimensions (l x w x d): 215 x 115 x 50 mm general description the new pmt series of panel mount power supplies is the latest offering from one of the world?s largest power supply manufact urers and solution providers - delta. the product offers a wide operating temperature range from - 10c to + 6 0c and ca n withstand shock and vibration requirements (in accordance to iec 60068 - 2 - 27 and iec 60068 -2 -6 respectively) . in addition to features like overvoltage and overload protections, delta?s pmt series of panel mount power supplies is unlike many other brands in the same p rice level. the pmt series is designed for cost competitive markets without compromising the quality of the components and product specificat ions. the series of products has an expected life time of 10 years. this versatile series has two different connect or options (terminal block and front face ) and can also be converted into l frame (pml) type of power supplies to satisfy different application needs. model information pmt panel mount power supply model number input v oltage range output v oltage output cur r ent pmt -24v200 w1a ?? 90- 132 vac , 180 - 264vac (selectable by switch) 24 vdc 8.8 0a model numbering cc code pm ? 24 v 20 0w 1 a panel mount product type t ? enclosed l ? l frame* output voltage output power single phase no pfc connector type m ? terminal block n ? front face* blank ? without connector cover a ? with connector cover *options
technical d at asheet pmt panel mount power supply 24v 200w 1 phase / pmt - 24v200w1a all parameters are specified at 25 c ambient unless otherwise noted. www. deltapsu .com ( august 2013 , rev. 0 0 ) 2 specifications input ratings / characteristics nominal input v oltage 100- 120v ac , 200 - 240vac (selectable by switch) input v oltage range 90- 132v ac , 180 - 264vac (selectable by switch) nominal input f r equency 50- 60hz input f r equency range 47- 63hz input cur r ent < 4.50a @ 115vac, < 2 .5 0a @ 230vac ef ficiency at 100% load > 8 8.5 % @ 230vac max inrush cur r ent < 5 5 a @ 230vac leakage cur r ent < 0.25 ma @ 240vac output ratings / characteristics nominal output voltage 24 vdc output voltage tolerance 1 % (initial set point tolerance from factory ) output voltage adjustment range 21.6 - 26.4 vdc output current 8.80a output power 211.2w line regulation 0.5% typ. (@ 100- 132vac & 200- 264vac ) load regulation 0.5 % typ. (@ 100 - 132vac & 200- 264vac ) pard (20mhz) < 1 5 0mvp p rise time 3 0ms typ. @ 115vac, 20ms typ. @ 230vac (100% load) start - up time 1 0 00ms typ. @ 115vac & 230vac (100% load ) hold - up time 2 0 ms typ. @ 115vac , 24ms typ. @ 230vac dynamic response (overshoot & undershoot o/p voltage) 5% @ 0 - 100% load start - up with capacitive loads 8,000f max mechanical case chassis aluminium case cover aluminium dimensions (l x w x d) 215 x 115 x 50 mm unit weight 0.63 kg indicator green led (dc ok) cooling system convection terminal pm?-24v 20 0w1a m ? m3.5 x 9 pins (rated 300v/15a) pm ? - 24v 20 0w1a n ? m3.5 x 9 pins (rated 300v/20a) wire awg 22 -1 2
technical d at asheet pmt panel mount power supply 24v 200w 1 phase / pmt - 24v200w1a all parameters are specified at 25 c ambient unless otherwise noted. www. deltapsu .com ( august 2013 , rev. 0 0 ) 3 environment surrounding air temperature operating -1 0c to + 6 0 c (cold start at - 20c) storage -2 5 c to + 85c power de - rating > 4 0c de - rate power by 2.5% / c < 1 00 vac de - rate power by 3 % / 1 v operating humidity 10-95 % rh (non - condensing) operating altitude 5 ,000 meters shock test (non - operating) iec 60068 -2 - 27, half sine: 5 0g for a duration of 11ms, 3 times for each 3 direction s vibration ( non - operating) iec 60068 -2 - 6, random: 5 hz to 5 00hz @ 2.09g rms, 2 0 min per axis for all x, y, z direction pollution degree 2 protections overvoltage 27.6 - 32.4v , hicc - up mode, n on- latch ing (auto - recovery) overload / overcurrent 1 05- 150% , hicc - up mode, non - latching (auto - recovery) over temperature hicc - up mode, non- latching (auto - recovery when the fault is removed) short circuit hicc -up mode, non - latching (auto - recovery when the fault is removed) protection against shock class i with pe* connection *pe: primary earth reliability data mtbf > 7 00,000 hrs. as per telcordia sr - 332 i/p: 100vac, o/p: 100% load, ta: 35 c expected cap life time 10 years (115vac & 230vac , 50% load @ 40c ) safety standards / directives electrical safety ul/cul recognized to ul 60950 -1 and csa c22.2 no. 60950 - 1, cb scheme to iec 60950 -1 material and parts rohs directive 2011/65/eu compliant galvanic isolation input to output 3 .0kvac input to ground 1.5kvac output to ground 0 .5kvac
technical d at asheet pmt panel mount power supply 24v 200w 1 phase / pmt - 24v200w1a all parameters are specified at 25 c ambient unless otherwise noted. www. deltapsu .com ( august 2013 , rev. 0 0 ) 4 emc emc / emissions * cispr 22, en 55022, fcc title 47: class a (with delta emi filter p/n: 10dkaw5) immunity to * en 55024 electrostatic discharge iec 61000 -4 - 2 level 4 criteria a 1) air discharge: 15kv contact discharge: 8kv radiated field iec 61000 -4 - 3 level 2 criteria a 1) 80mhz - 1ghz , 3v /m with 1khz tone / 80% modulation electrical fast transient / burst iec 61000 -4 - 4 level 3 criteria a 1) 2kv surge iec 610 00 -4 - 5 level 3 criteria a 1) common mode 2) : 2kv differential mode 3) : 1 kv conducted iec 61000 -4 - 6 level 3 criteria a 1) 150khz - 80mhz, 3 vrms power frequency magnetic fields iec 61000 -4 - 8 criteria a 1) 1 0 a/meter voltage dips iec 61000 -4 - 11 100% dip; 1 cycle (20ms); self recoverable low energy pulse test (ring wave) iec61000 - 4 -12 level 3 criteria a 1) common mode 2) : 2kv differential mode 3) : 1kv *fulfills tested conditions 1) criteria a: normal performance within the specificatio n limits 2) asymmetrical: common mode (line to earth) 3) symmetrical: differential mode (line to line) block diagram
technical d at asheet pmt panel mount power supply 24v 200w 1 phase / pmt - 24v200w1a all parameters are specified at 25 c ambient unless otherwise noted. www. deltapsu .com ( august 2013 , rev. 0 0 ) 5 device description 1 ) input & output terminal block connector 2 ) dc voltage adjustment potentiometer 3 ) dc ok control led (green) 4 ) ac selectable switch dimensions l x w x d: 215 x 115 x 50 mm (pmt - 24v200w1a m : terminal block with case cover) pmt - 24v200w1a m ? : terminal block pmt - 24v200w1a n ? : front face
technical d at asheet pmt panel mount power supply 24v 200w 1 phase / pmt - 24v200w1a all parameters are specified at 25 c ambient unless otherwise noted. www. deltapsu .com ( august 2013 , rev. 0 0 ) 6 l x w x d: 215 x 115 x 50 mm (pmt - 24v200w1a n : front face with case cover) l x w x d: 215 x 115 x 50 mm (pml - 24v200w1a m : terminal block without case cover)
technical d at asheet pmt panel mount power supply 24v 200w 1 phase / pmt - 24v200w1a all parameters are specified at 25 c ambient unless otherwise noted. www. deltapsu .com ( august 2013 , rev. 0 0 ) 7 l x w x d: 215 x 115 x 50 mm (pml - 24v200w1a n : front face without case cover)
technical d at asheet pmt panel mount power supply 24v 200w 1 phase / pmt - 24v200w1a all parameters are specified at 25 c ambient unless otherwise noted. www. deltapsu .com ( august 2013 , rev. 0 0 ) 8 engineering data de - rating output de - rating vs. input voltage note 1 . power supply components may degrade, or be damaged, when the power supply is continuously used outside the shaded region, refer to the graph shown in fig. 1. 2 . if the output capacity is not reduced when the surrounding air temperature >60 c, the device will run into over temperature protection. when activated, the output voltage will go into bouncing mode and will recover when the surrounding air temperature is lowered or the load is reduced as far as necessary to keep the device in working condition. 3 . in order for the device to function in the manner intended, it is also necessary to keep a safety distance of 20mm with adjacent units while the device is in operation. 4 . depending on the surrounding air temperature and output load delivered by the power supply, the device can be very hot! 5 . if the device ha s to be mounted in any other orientation, please do not hesitate to contact info@deltapsu.com for more details. fig. 1 de - rating for vertical and horizontal mounting orientation > 4 0c de - rate power by 2.5% / c ? no output power de - rating for the input voltage from 100vac to 132vac & 200vac to 264vac
technical d at asheet pmt panel mount power supply 24v 200w 1 phase / pmt - 24v200w1a all parameters are specified at 25 c ambient unless otherwise noted. www. deltapsu .com ( august 2013 , rev. 0 0 ) 9 assembly & installation ? side mounting: fig. 2 and fig. 3 show the mounting hole locations for power supply assembly onto a metal mounting surface. the power supply shall be mounted on minimum of 4 mounting holes using m4 screw of maximum 5mm length (refer to fig. 4). this is to maintain a safet y distance between the screw and internal components. ? base mounting: fig. 2 and fig. 3 show the mounting hole locations for power supply assembly onto a metal mounting surface. the power supply shall be mounted on minimum of 4 mounting holes using m4 screw of maximum 4mm length (refer to fig. 4). this is to maintain a safety distance between the screw and interna l components. ? c onnector ? this surface belongs to customer?s end system or panel where the power supply is mounted. base mounting (horizontal) base mounting (vertical) side mounting (horizontal) fig. 2 mounting orientation ? use flexible cable (stranded or solid) of awg no. 22 - 12. the input/output connectors? allowable current is 23a max per pin. user should calculate and select the suitable wire specification (type/quantity/diameter) according to actual output current. the torque at the c onnector shall not exceed 13kgf.cm. the insulation stripping length should not exceed 0.275? or 7mm. ? recommended mounting torque of the product and its mounting accessories is 9~12kgf.cm. fig. 4 assembly reference ? only use m4 screw 5 mm through the base mounting holes at . this is to keep a safe distance between the screw and internal components. only use m4 screw 4 mm through the base mounting holes at . this is to keep a safe distance between the screw and internal components. fig. 3 mounting hole locations and the safety distance t o ensure sufficient convection cooling, always maintain a distance of 20mm from ventilated surfaces while the device is in operation. please insert an insulation sheet between the system and product, if the safety distance is < 4mm.
technical d at asheet pmt panel mount power supply 24v 200w 1 phase / pmt - 24v200w1a all parameters are specified at 25 c ambient unless otherwise noted. www. deltapsu .com ( august 2013 , rev. 0 0 ) 10 improper installations safety instructions ? must select correct ac input voltage before turning on (refer to the ?device description? on page 5 ). ? the device is not recommended to be placed on low thermal conductive surface. for example, plastics. ? to ensure sufficient convection cooling, always maintain a distance of 20mm from ventilated surfaces while the device is in operation. please insert an insulation sheet between the system and product, if the safety distance is < 4mm. ? note that the enclosure of the device can become very hot depending on the ambient temperature and load of the power supply. do not touch the device while it is in operation or immediately after power is turned off. risk of b urning! ? do not touch the terminals while power is being supplied. risk of electric shock. ? prevent any foreign metal, particles or conductors from entering the device through the openings during installation. it may cause: - electric shock; safety hazard; f ire; product failure. ? warning: when connecting the device, secure earth connection before connecting l and n. when disconnecting the device, remove l and n connections before removing the earth connection. the power supply must be mounted by metal screws o nto a grounded metal surface. it is highly recommended that the earth terminal on the connector be connected to the grounded metal surface.
technical d at asheet pmt panel mount power supply 24v 200w 1 phase / pmt - 24v200w1a all parameters are specified at 25 c ambient unless otherwise noted. www. deltapsu .com ( august 2013 , rev. 0 0 ) 11 functions start - up time the time required for the output voltage to reach 90% of its set value, after the input vo ltage is applied. rise time the time required for the output voltage to change from 10% to 90% of its set value. hold - up time hold up time is the time when the ac input collapses and output voltage retains regulation for a certain period of time. the time required for the output to reach 95% of its set value, after the input voltage is removed. graph illustrating the start - up time, rise time, and hold- up time inrush current inrush current is the peak, instantaneous, input current measured and, occurs when the input voltage is first applied. for ac input voltages, the maximum peak value of inrush current will occur during the first half cycle of the applied ac voltage. this peak value decreases exponentially during subsequent cycles of ac voltage. dynamic response the power supply output voltage will remains within 5% of its steady state value, when su bjected to a dynamic load from 0 to 100% of its rated current.
technical d at asheet pmt panel mount power supply 24v 200w 1 phase / pmt - 24v200w1a all parameters are specified at 25 c ambient unless otherwise noted. www. deltapsu .com ( august 2013 , rev. 0 0 ) 12 overload & overcurrent protections the power supply?s overload (olp) and overcurrent (ocp) protections will be activated when output current exceeds 1 05- 150 % of i o (max load). in such occurrence, the v o will start to droop and once the power supply has reached its maximum power limit, the protection is activated and the power supply will go into ?hiccup mode? (auto - recovery). the power supply will recover once the fault condition of the olp and ocp is removed and i o is back within the specifications. it is not recommended to prolong the duration of i o when it is < 105 but >100%, since it may cause damage to the psu. overvoltage protection the power supply?s overvoltage circuit will be activated when its internal feedback circuit fails. the output voltage shall not exceed it s specifications defined on page 3 under ?protections?. over temperature protection as mentioned above, the power supply also has over temperature protection (otp). in the event of a higher operating temperature at 100% load, the power supply will run into otp when the operating temperature is beyond what is recommended in the de - rating graph. when activated, the output voltage will go into bouncing mode until the temperature drops to its normal operating temperature as recommended in the de - rating gra ph. short circuit protection the power supply?s output olp/ocp function also provides protection against short circuits. when a short circuit is applied, the output current will operate in ?hiccup mode?, as shown in the illus tration in the olp/ocp section on this page. the power supply will return to normal operation after the short circuit is removed.
technical d at asheet pmt panel mount power supply 24v 200w 1 phase / pmt - 24v200w1a all parameters are specified at 25 c ambient unless otherwise noted. www. deltapsu .com ( august 2013 , rev. 0 0 ) 13 operating mode ? redundancy operation in order to ensure proper redundancy operation for the power supply unit (psu), ensure that the output voltage difference bet ween the two units is kept at 0.45 ~ 0.50v for 24v supplies. follow simple steps given below to verify: step 1. measure o utput voltage of psu 1 and psu 2. if psu 1 is the master unit, then v o of psu 1 must be higher than psu 2. in order to set the output voltage, connect the power supply to 50% load and set the psu 1 and psu 2 output voltage. step 2. connect the right drr module, 20a as per the system requirement to the power supply units psu 1 and psu 2 at v in 1 & v in 2 respectively. step 3. connect the system load from v out . please note that output voltage v out from drr module will be = v o (output voltage of power supply ) ? v drop * (in drr module). ? parallel operation these drr modules can also be used for parallel function in order to increase the output power by n+1 (e.g. 2.5a + 2.5a = 5a or 2.5a + 2.5a + 2.5a = 7.5a) or current sharing, and thus increasing the power supply and system reliability. though the pmt -24v 20 0w1a  is not designed for current sharing, a good current sharing between two power supplies can be achieved by following simple steps as below (refer to fig. 3 for the connection diagram). *v drop will vary from 0.60v to 0.90v (typical 0.65v) depending on the load current and surrounding air temperature. fig. 5 redundancy / parallel operation connection diagram step 1 . set output load condition for both supplies at 50% and measure the output voltages. step 2. adjust output voltages to the same level or within 25mv difference. step 3 . connect psu 1 and psu 2 with the drr - 20a module and measure at v in 1 & v in 2 to verify the voltage difference. ensure the voltages are within 25mv. step 4 . output voltage from drr module v out will be = v o (output voltage of power supply) ? v drop * (in drr module).
technical d at asheet pmt panel mount power supply 24v 200w 1 phase / pmt - 24v200w1a all parameters are specified at 25 c ambient unless otherwise noted. www. deltapsu .com ( august 2013 , rev. 0 0 ) 14 others delta rohs compliant restriction of the usage of hazardous substances the european directive 2011/65/eu limits the maximum impurity level of homogeneous materials such as lead, mercury, cadmium, chrome, polybrominated flame retardants pbb and pbde for the use in electrical and electronic equipment. rohs is the abbreviation f or ?restriction of the use of certain hazardous substances in electrical and electronic equipment?. this product conforms to this standard.
mouser electronics authorized distributor click to view pricing, inventory, delivery & lifecycle information: delta: ? pmt-24v200w1am


▲Up To Search▲   

 